VIDEO AIR PLASMA ERROR CODES ON HYPERTHERM POWERMAX
VIDEO AIR PLASMA ERROR CODES ON HYPERTHERM POWERMAX
In this episode, Jim Colt talks about air plasma error codes on Hypertherm Powermax. He goes through the common error codes when starting up your plasma cutting torch. These codes are published in your Hypertherm manual as well as your operator control station on the MaverickCNC plasma cutting table.
HYPERTHERM POWERMAX45XP, 65, 85, 105, 125 PLASMA – WHAT MAKES THEM THE BEST AIR PLASMA SOURCES ON THE MARKET? MaverickCNC plasma tables utilize Hypertherm’s Powermax line of plasma systems. The systems available are the Powermax 45XP, 65, 85, 105, ...
Hypertherm Fault Codes Sometimes you will get fault alarms on your Powermax. You will see an amber light on the front of the system and a 0-## code on the screen. These will show if you have issues like low air, a stuck consumable or the retaining ...
WHY LOW AIR PRESSURE IS A PROBLEM FOR PLASMA CUTTING A very common problem with plasma cutting systems is low air pressure and/or insufficient air flow. This is particularly common with air plasma systems, relying on air supplied from a compressor as ...